Tech Tips

Case 2

Maintenance of HAKKO FV-310

If a failure phenomenon occurs
Maintenance of HAKKO FV-310
CASE1Although the motor is rotating, only cool air comes out.
CASE2The motor does not rotate and the heating element is not heated.
CASE3Air flow volume cannot be adjusted.
CASE 2. The motor does not rotate and the heating element is not heated.
The heating element is broken or the power cord is disconnected.

The heating element deteriorates gradually during use, eventually resulting in breakage. Open the housing to check the resistance value of the heating element.

*If the resistance value is abnormal, it indicates that the heating element is broken.

*If the resistance value is shown as normal, the motor is out of order or the power cord is disconnected.

If the heating element is broken

Please, replace it with a new one as it is available as a replacement part.

Replacement procedure
Please refer to the instruction manual for the heating element
Necessary tool#1 Cross driver (150mm long is recommended)
Part numberA5040 (110V), A5041 (220V), A5043 (230V), A5042 (240V)
If the heating element is not broken

The motor is out of order or the power cord is disconnected. The motor is available as an option, however, the repair service is recommended in case you are not a repair technicians. * The power cord is not available as a replacement part. It can be replaced only by repair service. For repair service, please, return the product back to the store it was purchased from.